Hi Gurus,
My device now generally passes 7 -8 kV contact discharge, but sometimes
fails at 3 kV (I am testing from 1 kV to 8 kV, 1 zap per second for about
15 seconds).  Can someone explain the reason for this behavior.

Thanks.

Regards, Ravinder
Server PCB and Flex Development
Hitachi Global Storage Technologies
***************************************************************************
Always do right.  This will gratify some people and astonish the rest.
.... Mark Twain



This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ewh.ieee.org/soc/emcs/pstc/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              [email protected]
     Dave Heald:               [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

Archive is being moved, we will announce when it is back on-line.
All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc