Hi All, Thanks to all who responded to my query. I will inform you of my findings as soon as I have a solution.
Kind Regards ALEX From: Alex McNeil Sent: Tuesday, June 17, 2003 10:09 AM To: '[email protected]' Subject: Transverse Balance Limitations 68.310_On Hook Hi Group, Can you help here. I pass the above FCC Part 68 specification when my product uses a Linear Power Supply but fail when I use my alternate Switch Mode Power Supply. Why should this be? Kind Regards Alex This message is from the IEEE EMC Society Product Safety Technical Committee emc-pstc discussion list. Visit our web site at: http://www.ewh.ieee.org/soc/emcs/pstc/ To cancel your subscription, send mail to: [email protected] with the single line: unsubscribe emc-pstc For help, send mail to the list administrators: Ron Pickard: [email protected] Dave Heald: [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] Archive is being moved, we will announce when it is back on-line. All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc