I read in !emc-pstc that Doug Massey <[email protected]> wrote (in
<003101c3a3c2$785cdac0$1001000a@Doug>) about 'Casino gaming machine' on
Wed, 5 Nov 2003:
>
>    Similar products by the client have been evaluated by a Notified 
>    Body lab in the Community; the standard used was EN 60065, Audio / 
>    Video.
>
This is a known mis-application of the standard. The EN 60335-2-82
standard is the correct one, but I don't have a copy.
-- 
Regards, John Woodgate, OOO - Own Opinions Only. http://www.jmwa.demon.co.uk 