In a message dated 12-12-2003, Ned Devine writes:
 
> Does the FCC testing for Modem’s require the testing in UL 60950-1, clause
6.4 Protection against 
> overvoltage from power line crosses?  I looked at the requirements in FCC
part 68 and didn’t see anything 
> similar.  But I wanted to make sure.
 
 
Hi Ned:
 
FCC Part 68 does not call out UL 60950-1.  The main focus of FCC Part 68 is
preventing harm to phone network.
 
UL 60950-1 is not explicitly called out in any Federal laws, but many local
and regional regulations and customer specifications call for appropriate
safety certifications.  As a practical matter, it is almost always necessary
to test for UL 60950-1 as well as FCC part 68.
 
 
Joe Randolph
Telecom Design Consultant
Randolph Telecom, Inc.
781-721-2848 (USA)
[email protected]
http://www.randolph-telecom.com