In a message dated 12-12-2003, Ned Devine writes:
> Does the FCC testing for Modem’s require the testing in UL 60950-1, clause
6.4 Protection against
> overvoltage from power line crosses? I looked at the requirements in FCC
part 68 and didn’t see anything
> similar. But I wanted to make sure.
Hi Ned:
FCC Part 68 does not call out UL 60950-1. The main focus of FCC Part 68 is
preventing harm to phone network.
UL 60950-1 is not explicitly called out in any Federal laws, but many local
and regional regulations and customer specifications call for appropriate
safety certifications. As a practical matter, it is almost always necessary
to test for UL 60950-1 as well as FCC part 68.
Joe Randolph
Telecom Design Consultant
Randolph Telecom, Inc.
781-721-2848 (USA)
[email protected]
http://www.randolph-telecom.com