The antenna is calibrated in free space, its use must simulate that with no
loading of the antenna.

> From: "Luke Turnbull" <[email protected]>
> Reply-To: "Luke Turnbull" <[email protected]>
> Date: Fri, 05 Mar 2004 15:30:54 +0000
> To: <[email protected]>
> Subject: Chamber radiated emissions question.
> 
> 
> Dear all,
> 
> CISPR 25 has some requirements for the proximity of EUT and antennas to the
> screened enclosure:
> 
> 1.  No closer than 1m from any absorber.
> 2.  No closer than 2m from the chamber wall.
> 
> Does anybody know the technical reasons for these requirements?
> 
> Thanks in advance,
> 
> Luke Turnbull
> 
> 
> 
> -------------------------------------------
> This message is from the IEEE EMC Society Product Safety
> Technical Committee emc-pstc discussion list.
> 
> Visit our web site at:  http://www.ieee-pses.org/
> 
> To cancel your subscription, send mail to:
> [email protected]
> with the single line:
> unsubscribe emc-pstc
> 
> For help, send mail to the list administrators:
> Ron Pickard:              [email protected]
> Dave Heald:               [email protected]
> 
> For policy questions, send mail to:
> Richard Nute:           [email protected]
> Jim Bacher:             [email protected]
> 
> All emc-pstc postings are archived and searchable on the web at:
> http://www.ieeecommunities.org/emc-pstc
> 



This message is from the IEEE EMC Society Product Safety
Technical Committee emc-pstc discussion list.

Visit our web site at:  http://www.ieee-pses.org/

To cancel your subscription, send mail to:
     [email protected]
with the single line:
     unsubscribe emc-pstc

For help, send mail to the list administrators:
     Ron Pickard:              [email protected]
     Dave Heald:               [email protected]

For policy questions, send mail to:
     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:
    http://www.ieeecommunities.org/emc-pstc

Reply via email to