http://www.ieee-pses.org/symposium http://www.emc2004.org/
-------------------------------------------------- 
I want to bond my PCBs to my metal housing effectively for many reasons:
mechanical, thermal, electrical safety and EMC etc.
I know there are a lot of safety related threads we have talked about on this
topic in the past -
But my practical focus right now is getting a bond without tearing up the pads
while still being effective for all those design issues.
I am looking for your advice on the best approach - all tangents welcome but
be sure to address the practical topic as well.
 
Background
I have 9 PEM nut stand offs that support the board which take # 6 size screws
that come in from the top side of the PCB with standard internal star toothed
electrical lock washers.  6 of these are nickel plated brass hex standoffs
(with male thread on one side)and the remaining 3 are white zinc panheads. 
I understood that these internal toothed designs help give a bite and provide
a gas tight seal on metal surfaces.
My product is used in an industrial enviroment with large thermal swings and
occasional condensation.
The product also needs to perform for at least 10 years.

*       Question 1 - Does this gas tight topic apply to the plated through hole 
pads
of a PCB if the surface is tined copper?  


*       What about the gold treatments used when there are fine pitch BGAs?  I 
have
that gold treatment on my board.

*       Question 2 - What is the optimum plating for the screw, lock washer and 
PEM
nut? 

*       Question 3 - I could adjust the solder paste mask to apply solder to the
Plated through hole surface to give more material to connect with - good idea? 

*       Question 4 - What is a practical weight for the copper on the top and 
bottom
of a .090" 10 layer board that must support fine pitched BGAs? 

*       Question 5 - Are there better styles of lock washers to use?  I have 
heard
of some dimpled styles that may be more forgiving. 

*       Queston 6 - Are there any form of pastes added to the threads or other
treatments to the bond in general that would help?  


*       Note that my production group wants to keep it simple and I must 
justify all
extra procedures.  For example I had captive washers on the screws so they did
not have to add it by hand.  

Thanks
 
Chris Wells
Senior Design Engineer  - Eaton Electrical
[email protected]
------------------------------------------- 

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. 


IEEE PSES Main Website: http://www.ieee-pses.org/ 


To post a message send your e-mail to [email protected] 


Instructions for use of the list server: 


http://listserv.ieee.org/listserv/request/user-guide.html 


List rules: http://www.ieee-pses.org/listrules.html 