[email protected] wrote (in <ofc2098c0b.954ca8c2-on86257019.003a5afa-86257019.003ba...@mmm.com>) about 'Human Exposure to EMF', on Tue, 7 Jun 2005: >Is anyone familiar with standards on Human Exposure to Electromagnetic >Fields? I am trying to compile a list of existing and upcoming >standards. I have the following: > >* EN 50364 (and EN 50357), EAS/RFID, April 1, 2004 (RTTED) >* EN 50366, Household appliances and hand tools, Feb. 1, 2006 (LVD) >* EN 50371, Generic (low power electronic/electrical apparatus), Oct. >1, 2004 (RTTED) >* EN 50392, Generic (electronic/electrical apparatus), Oct. 1, 2006 > >What about the FCC? Other countries?
From the public part of the IEC web site (www.iec.ch): You can buy the following: Publications issued by TC 106 Publication Language IEC 62209-1 (2005-02) English and French Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz) IEC 62226-1 (2004-11) English and French Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 1: General IEC 62226-2-1 (2004-11) English and French Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 2-1: Exposure to magnetic fields - 2D models Working documents for TC 106 Since: 7 June 2004 The following documents are not in the public domain. You would have to ask you National Committee that parallels IEC TC106 for copies: 106/92/RVC Download file in: PDF format ( 187 kB); (password required) Result of voting on 106/70/CDV: Generic product standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz) 106/91/RVC Download file in: PDF format ( 81 kB); (password required) Result of voting on 106/77/CDV: Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure 106/90/NP Download file in: PDF format ( 1 288 kB); (password required) Voting Result Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures Part 2: Procedure to determine the Specific Absorption Rate (SAR) in the head and body for 30 MHz to 6 GHz Handheld and Body-Mounted Devices used in close proximity to the Body. 106/88/RVD Download file in: PDF format ( 200 kB); (password required) Report of Voting on 106/84/FDIS: IEC 62209-1 Ed.1: Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the Specific Absorption Rate (SAR) for hand-held devices used in close proximity of the ear (frequency range of 300 MHz to 3 GHz) 106/87/NP Download file in: PDF format ( 109 kB); (password required) Voting Result Determination of RF fields in the vicinity of mobile communication base stations for the purpose of evaluating human exposure. 106/86/RVN Download file in: PDF format ( 205 kB); (password required) Result of voting on 106/72/NP: Methods for calculating the current density and internal electric field induced in the human body by electric or magnetic fields in the low and intermediate frequency range. Part 3: Electric Field 106/85/RVN Download file in: PDF format ( 174 kB); (password required) Result of voting on 106/75/NP: Measurement procedures for electric and magnetic fields generated by AC power lines with regard to human exposure 106/84/FDIS Voting Result Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the Specific Absorption Rate (SAR) for hand-held devices used in close proximity of the ear (frequency range of 300 MHz to 3 GHz) 106/83/RVD Download file in: PDF format ( 35 kB); (password required) Report of Voting on 106/79/FDIS: IEC 62226-2-1 Ed.1: Exposure to electric and magnetic fields in the low and intermediate frequency range - Method for calculating the current density and internal electric field induced in the human body - Part 2-1: Exposure to magnetic fields - 2D models 106/82/RVD Download file in: PDF format ( 118 kB); (password required) Report of Voting on 106/78/FDIS: Project: IEC 62226-1 Ed.1: Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 1: General 106/81/PW Download file in: WORD format ( 71 kB); PDF format ( 151 kB); (password required) Programme of work of the technical committee as recorded by the IEC Central Office in its database 106/80/CD Download file in: PDF format ( 2 596 kB); (password required) IEC 62369-1 Ed. 1: Evaluation of human exposure to electromagnetic fields from Short Range Devices (SRDs) in various applications over the frequency range 0-300 GHz. Part 1: Fields produced by devices used for Electronic Article Surveillance, Radio Frequency Identification and similar systems. 106/79/FDIS Voting Result Exposure to electric and magnetic fields in the low and intermediate frequency range - Method for calculating the current density and internal electric field induced in the human body - Part 2-1: Exposure to magnetic fields - 2D models 106/78/FDIS Voting Result Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 1: General 106/77/CDV Download file in: PDF format ( 626 kB); (password required) Other authorized committees:61 Voting Result Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure 106/76/RVC Download file in: WORD format ( 423 kB); PDF format ( 325 kB); (password required) Result of voting on 106/61/CDV: IEC 62209-1: Specific Absorption Rate (SAR) in the frequency range of 300 MHz to 3 GHz - Measurement procedure - Part 1: hand-held mobile wireless communication devices 106/66A/CC Download file in: WORD format ( 1 343 kB); PDF format ( 1 400 kB); (password required) Revised compilation of comments on 106/58/CD: IEC 62233: Measurement methods for low frequency magnetic and electric fields of domestic appliances with regard to human exposure 106/75/NP Download file in: PDF format ( 1 544 kB); (password required) Voting Result Measurement procedures for electric and magnetic fields generated by AC power lines with regard to human exposure -- Regards, John Woodgate, OOO - Own Opinions Only. Deadlines are 90% of deadliness. http://www.jmwa.demon.co.uk Also see http://www.isce.org.uk This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/listserv/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Richard Nute: [email protected] Jim Bacher: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc