Jim Collum wrote:

>> Could anyone who has done something like this in the past tell me....
1) Did you use a specialist company to dismantle/reassemble and verify
seals etc or did you do it yourself?
2) Any recommendations on specifying electrical requirements in the
proposed new location.
3) Have you ever left the room behind and just purchased new again, if
so why, Cost? Previous attempts to relocate proved problematic? A good
excuse to upgrade? <<

I helped move a copper screen room while I was in Fort Worth. We'd moved
our lab and gotten better chambers built there.   

The one I mention was transferred to another group, who actually did all
the grunt work. Since I had *built* that chamber (from pieces of two very
old Lindgren chambers of different sizes) I didn't hesitate. It was moved
>from the basement of one building to the 10th floor of an adjoining one
that shared a common basement. (If you remember the Tandy Center you know
what I mean.)  Because of its origins, it never had to meet any particular
shielding standard, which was a good thing, as I never got better than
about 60 dB from it.   That said, there's no reason a chamber of better
quality could not be brought up to 100 dB with some care in reassembly. 

As I recall, there was already electrical service enough that the new
owners had no need to specify it; their EUT's and instruments needed
nowhere near what was already installed. The possible exception might have
been 220V 50 Hz, which was from a remote rotary converter. I know ours was
brought up to the new chambers we got.

Removing and replacing anechoic materials adds a whole new set of
headaches, though. I'd want to contract that case out.


Cortland Richmond


This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/listserv/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas             [email protected]
     Mike Cantwell            [email protected]

For policy questions, send mail to:

     Richard Nute:           [email protected]
     Jim Bacher:             [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to