Ian,

I would expect a power supply to function according to its
specifications.
This means that all output voltages have to stay within the specified 
tolerance limits.

Best regards,
Michael

Michael Nagel
Senior EMC Engineer
Motorola GmbH
ECC Embedded Communications Computing
Lilienthalstrasse 15
85579 Neubiberg/Muenchen - Germany
Ph: +49-89-9608-0 
Fax: +49-89-9608-2376 
e-mail: [email protected]  
info: http://www.motorola.com/computers 



From: [email protected] [mailto:[email protected]] On Behalf Of
[email protected]
Sent: Thursday, May 18, 2006 3:47 PM
To: [email protected]
Subject: Burst and surge tests

Dear Group,

I have a question regarding the likely behaviour of ac to dc switch mode
power supplies during fast transient burst tests to EN 61000-4-4 and
surge tests to EN 61000-4-5.

For a manufacturer to claim conformity to these standards are any
constraints placed on the behaviour of the dc output voltage during the
tests? I am particularly interested in the likely change in DC voltage
output as the appropriate burst/surges are applied to the ac input.

Many thanks in anticipation of your replies.

Best regards

Ian Unwin
Lead Engineer
Servomex Group Limited


*********************************************
*Register now at www.servomex.com/zap.html  *
*for an opportunity to win a great prize    *
*in our monthly draw.                       *
*********************************************
________________________________________________________________________
This email has been scanned for all viruses by the MessageLabs SkyScan
service. 
This electronic message contains information from Servomex which may be
privileged or confidential. The information is intended to be for the
use of the individual(s) or entity named above. If you are not the
intended recipient be aware that any disclosure, copying, distribution
or use of the contents of this information is prohibited. If you have
received this electronic message in error, please notify us immediately.
Activity and use of the Servomex E-mail system is monitored to secure
its effective operation and for other lawful business purposes.

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

Reply via email to