HI All, I've been asked a question about UL864 for smoke control systems. This requires surges of around 2400V to be applied to all IO lines including the Ethernet port. Are there any design specification limitations I soul be worried about implementing suppression for this pulse. I specifically mean, can I use MOV's Transorbs to chassis etc? I was under the impression that Ethernet could be transformer isolated, and then I'd let the transformer take care of the surge... Any thoughts would be appreciated. Derek Walton L F Research
______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please visit http://www.messagelabs.com/email ______________________________________________________________________ - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc