In message <[email protected]>, dated Mon, 12 Jun 2006, Charles Blackham <[email protected]> writes
>However as Point-of-Sale equipment is not typically domestic equipment, >if you can state categorically that this is the case, you could write a >draft TCF and ask a Competent Body to give you an opinion to clause >3.1b of the R&TTE directive. The crunch argument would be that no TV or radio receivers would be likely to be within 10 m (preferably 30 m) of the product. -- OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk 2006 is YMMVI- Your mileage may vary immensely. John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc