Hello Gary,

I have been waiting to see if anybody else would answer your question.
Since nothing has come through the mailing list yet, I might as well throw
in my opinion.

I can find nothing in CISPR 22 that specifically exempts ports used only
for setup or maintenance.  However, this is the general practice.  The
standard require testing typical applications.  You can make two arguments.
First, the connection to the port is not typical.  It is only done for
short periods of time.  Second, the connection is temporary.  If the
connection does cause interference, you can disconnect the port.  In most
cases, you can move the device for service to where it causes no
interference, connect the port when the victim device is off or live with
the interference for the period that the port needs to be used.

My experience has been that test laboratories do not require connection of
these ports for testing.  For devices used in environments with life safety
equipment, the requirement may be different.

Ted Eckert
American Power Conversion/MGE
http://www.apc.com/

The items contained in this e-mail reflect the personal opinions of the
writer and are only provided for the assistance of the reader. The writer
is not speaking in an official capacity for APC-MGE or Schneider Electric.
The speaker does not represent APC-MGE's or Schneider Electric's official
position on any matter.


                                                                           
             "McInturff Gary"                                              
             <GMcInturff@spray                                             
             cool.com>                                                  To 
             Sent by:                  <[email protected]>                 
             [email protected]                                          cc 
                                                                           
                                                                   Subject 
             05/02/2007 05:19          Maintenance ports                   
             PM                                                            
                                                                           
                                                                           
                                                                           
                                                                           
                                                                           




I seem to recall that an ITE port that was used only during maintenance
intervals didn’t necessarily have to be loaded as part of the emissions
tests. I was just looking in C63.4 for that point but did not find it. Was
it ever there or am I delusional again. How about CISPR?
Thanks
Gary


- ---------------------------------------------------------------- This
message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. Website: http://www.ieee-pses.org/


To post a message to the list, send your e-mail to [email protected]


Instructions: http://listserv.ieee.org/request/user-guide.html


List rules: http://www.ieee-pses.org/listrules.html


For help, send mail to the list administrators:


Scott Douglas [email protected] Mike Cantwell [email protected]


For policy questions, send mail to:


Jim Bacher: [email protected] David Heald: [email protected]


All emc-pstc postings are archived and searchable on the web at:


http://www.ieeecommunities.org/emc-pstc

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

Reply via email to