Dear group, I had a question as to the meaning of "upper" in V-3/2007.04 clause 1. The response I received from VCCI is below, which also clarifies the implementation of the telecom port conducted testing requirement.
Best regards, Bill stumpf DLS Electronic Systems, Inc. 262-279-0210 Dear Bill Stumpf, I'm Jiro Kawano, Technical Manager. It is surely misunderstanding the word "upper". Please neglect the word "upper", the meaning is unchanged I think. Yes, now is the consideration period for Telecom Port Conducted Measurement. In this time frame, will mandatory from three years after, 2010 April, but not confirm now. Regards, *********************** VCCI Office Jiro Kawano 81-3-5575-3138 Fax 81-3-5575-3137 e-mail [email protected] From: [email protected] [mailto:[email protected]] On Behalf Of T.Sato Sent: Saturday, June 02, 2007 7:01 AM To: [email protected] Cc: [email protected] Subject: Re: Telecom Port Testing For VCCI On Fri, 1 Jun 2007 16:24:55 EDT, [email protected] wrote: > Does anyone know when Japan (VCCI) will require telecom port conducted > emission testing for Ethernet ports on ITE? I believe VCCI and FCC > are supposed to adopt the new CISPR standards. Yes, VCCI already adopted CISPR 22:2005. However, at this time, in the Technical requirements V-3/2007.04 clause 1, they wrote: Enforcement of upper limits of conducted disturbance at the telecommunication ports is under consideration. Regards, Tom Tomonori Sato <[email protected]> URL: http://homepage3.nifty.com/tsato/ - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc ______________________________________________________________________ This email has been scanned by the MessageLabs Email Security System. For more information please visit http://www.messagelabs.com/email ______________________________________________________________________