Hello,

In my copy of RTCA DO-160E it is 1 kHz. Version F will be the same, I
believe.

Regards,
 
Paul Scott, NCT
Senior EMC Technologist, Lab Supervisor
Electronics Test Centre (ETC)
302-100 Legget Drive
Ottawa, ON
Canada
K2K 1Y5
Tel: (613) 599-6800
Fax: (613) 599-7614
[email protected]
 

NOTICE: This e-mail message, plus any and all attachments, are
confidential communications between the Electronics Test Centre and the
named recipients. If this message is inadvertently sent to anyone other
than the intended recipients, all copies are to be erased immediately,
and the sender must be notified of the transmittal error. Named
recipients of this e-mail message may freely distribute this message
and/or attachments within their company as required for business
purposes.

 


From: [email protected] [mailto:[email protected]] On Behalf Of Ken
Javor
Sent: Wednesday, August 08, 2007 4:19 PM
To: [email protected]
Cc: Group, IEEE EMC Discussion
Subject: RTCA/DO-160E Section 21 emission measurement bandwidths

I am measuring dc/dc converter emissions against the RTCA/DO-160 section
21
CE limit (class L). Above about 20 MHz, there are some BB emissions. If
I
use a 9 kHz BW, they just fail.  At 1 kHz BW, they pass.  My copy of
RTCA/DO-160D says to use 1 kHz BW over the CE frequency range (0.15 - 30
MHz).  That seems kind of low to me. Can anyone confirm the same
bandwidth
is used for DO-160E as well, or if it has maybe increased?

Thank you,

Ken Javor 

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

-

This message is from the IEEE Product Safety Engineering Society
emc-pstc discussion list.    Website:  http://www.ieee-pses.org/

To post a message to the list, send your e-mail to [email protected]

Instructions:  http://listserv.ieee.org/request/user-guide.html

List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:

     Scott Douglas           [email protected]
     Mike Cantwell           [email protected]

For policy questions, send mail to:

     Jim Bacher:             [email protected]
     David Heald:            [email protected]

All emc-pstc postings are archived and searchable on the web at:

    http://www.ieeecommunities.org/emc-pstc

______________________________________________________________________
This email has been scanned by the MessageLabs Email Security System.
For more information please visit http://www.messagelabs.com/email 
______________________________________________________________________

Reply via email to