We are considering placing an OATS on the roof top of a building for
some inhouse testing. Does anyone have any experince with OATS on roof
tops? To our lab we may be required to run 60' of cable from our
antenna. Does 60' sound too long? We would like to get good site
attenuation out to 1GHz. Also any suggestions on material for the ground
plane would be appreaciated. Since we will be running the grounding
conductors before we can test the site, we wonder if we should provide
more than one ground connection to the plane.

Thanks,
Cody

-