Hi Experts, I am looking for regulatory information (Safety and EMC) for the mentioned (see below) luminaries. I think the best way is to use the "CB Scheme route" to show compliance for the relevant IEC standards. I hope that it works for Russia (GOST-mark), Japan (PSE/S-mark), China (CCC-mark), Australia (RCM and c-tick-mark), South Korea (EK-mark), India (S- or ISI-mark), Brazil (INMETRO) but... Who has information for the Countries of the Gulf - UAE, Qatar, Oman, Saudi Arabia, Kuwait and additionally Thailand? I knows that these countries aren´t "CB members". Does these countries accept nonetheless "CB certficates" or are additional national certifications required? Have they "mandatory national marks" in accordance to specific laws (EMC? safety)? Description
Product Platform of Luminaries Concept: One design is used for several versions of luminaries, i.e. as many components as possible are used for different sizes or different mounting alternatives (refer to illustration). These luminaries have got a lots of light points (LED or Halogen) which illuminate glas components (fixed to the housings) and create twinkling effects. Voltage: All versions of this luminaire are available with wide-range input: 100…240V Critical components: 1.Power Supply LED converter or Halogen electronic converter with § VDE or TÜV approval (220-240 Volts, 50/60 Hz) or § UL or CSA approval (100-127 Volts, 50/60 Hz) 2. LEDs: 0,1 – 2 Watts, constant current 700mA or 24 Volts, e.g. Osram Backlight BL02 or Philips Luxeon Star/ K2 Star 3. Halogen: Bulb off-the-shelf, e.g. Osram Halogen bulb 20W, 12Volts 4. Option: Radio or infrared remote control (Wireless – WiFi, e.g. PDA or IR: Battery handheld e.g. DALI EASY RMC FS1) Description: Luminaires create sparkling and twinkling effects due to glas components. Decorative light/Functional light – but the primary purpose of the luminaries is to act as decorative light, i.g. most of these pieces are used in living/dining rooms, hotel lobbies/rooms or shopping centres. Version A: Ceiling mounted / PSU in housing / LED * Canopy made of metal or plastics * Power supply unit (PSU) in the housing connected to the mains (100-240 Volts) * Power supply unit: electronic LED converter (24 Volts constant voltage converter or 700mA constant current converter) * Harness from canopy to housing (100-240 Volts) * Housing (made of metal or plastics) is suspended by stainless steel cable (maximum length: 3 meters/120 inches) * Wight of the Housing: depends on size, between 20 and 100 kilograms (between 44 lb and 220 lb) * Illuminant: LEDs (mounted to the housing) Version B: Ceiling mounted / PSU in canopy / LED * Canopy made of metal or plastics * Canopy could be recessed in the ceiling * Power supply unit (PSU) in the canopy connected to the mains (100-240 Volts) * Power supply unit: electronic LED converter (24 Volts constant voltage converter or 700mA constant current converter) * Harness from canopy to housing (24 Volts or 700mA) * Housing (made of metal or plastics) is suspended by stainless steel cable (maximum length: 3 meters/120 inches) * Wight of the Housing: depends on size, between 20 and 100 kilograms (between 44 lb and 220 lb) * Illuminant: LED (mounted to the housing) Version C: Ceiling mounted / PSU in canopy / Halogen * Canopy made of metal or plastics * Canopy could be recessed in the ceiling * Power supply unit (PSU) in the canopy connected to the mains (100-240 Volts) * Power supply unit: electronic LED converter (24 Volts constant voltage converter or 700mA constant current converter) * Harness from canopy to housing (24 Volts or 700mA) * Housing (made of metal or plastics) is suspended by stainless steel cable (maximum length: 3 meters/120 inches) * Wight of the Housing: depends on size, between 20 and 100 kilograms (between 44 lb and 220 lb) * Illuminant: Halogen bulbs (mounted to the housing) Version D: Wall mounted / PSU in canopy / LED * Canopy made of metal or plastics * Power supply unit (PSU) in the canopy connected to the mains (100-240 Volts) * Power supply unit: electronic LED converter (24 Volts constant voltage converter or 700mA constant current converter) * Housing (made of metal or plastics) * Wight of the Housing: depends on size, 20 and 100 kilograms (between 44 lb and 220 lb) * Illuminant: LEDs (mounted to the housing) Version E: Floorlamp / PSU in housing / LED / portable * Plug: Connect the plug to a mains socket (100-240 Volts) * Power supply unit (PSU) in the housing connected to the mains (100-240 Volts) * Power supply unit: electronic LED converter (24V constant voltage converter or 700mA constant current converter) * Housing (made of metal or plastics) * Wight of the Housing: depends on size, between 20 and 100 kilograms (between 44 lb and 220 lb) * Illuminant: LED (mounted to the housing) Version F: Table lamp / PSU in housing / LED / portable * Plug: Connect the plug to a mains socket (100-240 Volts) * Power supply unit (PSU) in the housing connected to the mains (100-240 Volts) * Power supply unit: electronic LED converter (24V constant voltage converter or 700mA constant current converter) * Housing (made of metal or plastics * Wight of the Housing: depends on size, max. 20 kilograms (max. 44 lb) * Illuminant: LED (mounted to the housing) Option (for all Versions): Luminaire could be controlled by radio or infrared remote control. Mit freundlichen Grüßen Yours sincerely Dipl.-Ing. Michael Loerzer Managing Director Regulatory Affairs Specialist Fon: +49 30 3229027-50, Direct Call: -51 Mobile: +49 170 3229027 (new) Fax: +49 30 3229027-59 www.Globalnorm.de <http://www.globalnorm.de/> Globalnorm GmbH, Sitz der Gesellschaft: Alt-Moabit 94, 10559 Berlin Geschaeftsfuehrer: Dipl.-Ing. Michael Loerzer Amtsgericht Berlin-Charlottenburg HRB 105204 B, USt-ID-Nummer: DE251654448 - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. Website: http://www.ieee-pses.org/ To post a message to the list, send your e-mail to [email protected] Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas [email protected] Mike Cantwell [email protected] For policy questions, send mail to: Jim Bacher: [email protected] David Heald: [email protected] All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc