In message 
<ofe8a46d00.7b962aff-on8625790c.0059e33c-8625790c.005a6...@mmm.com>, 
dated Thu, 15 Sep 2011, [email protected] writes:

>"Commercial equipment" is not specifically called out in CISPR 22 but 
>in one paragraph it talks about using "actual equipment" as 
>peripherals. I take "actual" to mean the stuff that the user would be 
>using even though the word does not specifically mean "commercially 
>available".

Very sensible, because the actual equipment to be connected might be 
custom stuff, and the EUT needs to pass with that stuff, not with 
something else.
-- 
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK
When I point to a star, please look at the star, not my finger. The star will
be more interesting.

-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to