In message
<OF0F5CCAAE.4D0D8263-ON88257959.00750954-88257959.00753ECC@US.Schneider-E
lectric.com>, dated Thu, 1 Dec 2011,
[email protected] writes:
And by "response" do you mean the time-constant used in a typical AM
receiver AVC? .
I think it's the attack time-constant that is associated with the
response of a 4 kHz wide band-pass filter to a < 1 ms pulse. There is a
similarity between the decay time-constant and the AGC time-constant,
but I think the slow decay is much more associated with the ease of
reading the pointer meter than anything else.
--
OOO - Own Opinions Only. Try www.jmwa.demon.co.uk and www.isce.org.uk
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK
Some people who are peeling the finch of the financial crisis are thinking of
biting a rook.
-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc discussion
list. To post a message to the list, send your e-mail to <[email protected]>
All emc-pstc postings are archived and searchable on the web at:
http://product-compliance.oc.ieee.org/
Graphics (in well-used formats), large files, etc. can be posted to that URL.
Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>
For policy questions, send mail to:
Jim Bacher: <[email protected]>
David Heald: <[email protected]>