Ryan,
 

        Proper layout is the fix, the transformer has the straddle signal 
ground and
chassis ground planes. These planes should never overlap.

         

        Another trick I found is to stitch a 2kV/0.001micro farad SMD capacitor
across sig gnd and chassis gnd.

         

         

I don't understand why to avoid capacitance between signal gnd and chassis gnd
planes and at the same time use the capacitor between them ?
 
Regards
 
Piotr Galka
-