In message 
<d7b00ba5b5a75d44abb5117414b1341b03411...@eld-exch1.europe.echostar.com>, 
dated Mon, 2 Nov 2009, "Pawson, James" <[email protected]> 
writes:

>1) Does anyone know which section of the standard contains the info on 
>screening effectiveness measurements?

None.

>2) Do I need the 61196-1-1 generic standard too or just the specific 
>61196-1-1xx?

Probably not.

>3) Is this even the correct standard?

Probably not: look at IEC 61726 and the multi-part IEC 62153.
-- 