Hi We do something like this, and just state in the report that all emission over the limited have been verified to be background be switching off the EUT.
Best regards, Mr. Kim Boll Jensen Bolls Rådgivning Ved Gadekæret 11F DK-3660 Stenløse Phone: +45 48 18 35 66 [email protected] www.bolls.dk Fra: [email protected] [mailto:[email protected]] På vegne af Derek Walton Sendt: 14. april 2009 22:31 Til: [email protected] Cc: [email protected] Emne: Re: Radiated Emission Reports when using an OATS HI Cody, we perform pre-scan and the do final measurements on an OATS. In the body of the test report I address our process. I also give the reader confidence that we know what were doing on an OATS by citing some of the techniques we use to discriminate signals from interference. The report only contains data on the EUT. I hope this helps Sincerely, Derek Walton L F Research [email protected] wrote: > Dear All, > > How do EMC test houses handle interference within test reports when > using an OATS? Will they report a full prescan with all the > interference or do they only report quasi peaked points and their > values. We have been using a precompliance chamber for internal > testing and we just finished an OATS to improve our > precompliance testing and I am working on the reporting procedure for > the OATS data. Any input would be appreciated. > > Thanks, > Cody > - > ---------------------------------------------------------------- > This message is from the IEEE Product Safety Engineering Society > emc-pstc discussion list. To post a message to the list, send your > e-mail to <[email protected] <mailto:[email protected]>> > > All emc-pstc postings are archived and searchable on the web at > http://www.ieeecommunities.org/emc-pstc > Graphics (in well-used formats), large files, etc. can be posted to > that URL. > > Website: http://www.ieee-pses.org/ > Instructions: http://listserv.ieee.org/request/user-guide.html > List rules: http://www.ieee-pses.org/listrules.html > > For help, send mail to the list administrators: > Scott Douglas <[email protected] <mailto:[email protected]>> > Mike Cantwell <[email protected] <mailto:[email protected]>> > > For policy questions, send mail to: > Jim Bacher <[email protected] <mailto:[email protected]>> > David Heald <[email protected] <mailto:[email protected]>> > - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]> - This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieeecommunities.org/emc-pstc Graphics (in well-used formats), large files, etc. can be posted to that URL. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>