Notice that although the R&TTE Directive does not mention NB number height
directly... the Commission's R&TTE Guidance document states (advises?) that
the NB number should be the same height as the CE Mark.

 

I think Charlie's suggestion makes good sense but be warned that an
enthusiastic surveillance authority could ask questions.

 

Michael.

 

 

Michael Derby

Regulatory Engineer

ACB Europe

 

From: Charlie Blackham [mailto:[email protected]] 
Sent: 06 June 2012 09:19
To: [email protected]
Subject: Re: [PSES] Two Notified Body numbers on a product

 

Amund

 

Yes - put two NB numbers next to the CE mark - this can be done by placing
the two number on top of each other next to the CE mark such that their
total height is same as that of CE mark

 

Regards

Charlie

 

From: Amund Westin [mailto:[email protected]] 
Sent: 06 June 2012 04:46
To: [email protected]
Subject: [PSES] Two Notified Body numbers on a product

 

A product has to fulfill the EU directives RTTE and CPR. Two different
Notified Bodies are involved for the directives.

Are we talking about double NB numbering on the CE label?

 

So far, I have not seen any product with two NB identification numbers ...

 

#Amund

 

 

-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in
well-used formats), large files, etc.

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 

-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in
well-used formats), large files, etc.

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to