Hello Jasmine,

 

The most official and ‘legal’ document is this one.

http://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2009:289:0019:002
0:EN:PDF

It was written in 2009 and shows that the French restriction expires from
1st July 2012.

 

As additional guidance, the European Commission post this page on ‘Class 1’
devices.

http://ec.europa.eu/enterprise/sectors/rtte/files/rtte_subclass_july2012_en.
pdf

You can see sub-class 22 is for WLAN devices.

In June, it said  “2400-2454 MHz”   Now, from July, it says  “2400-2483.5
MHz”

 

I hope this helps,

 

Michael.

 

 

Michael Derby

Regulatory Engineer

ACB Europe

 

From: jasmine tan [mailto:[email protected]] 
Sent: 10 August 2012 09:03
To: [email protected]
Subject: [PSES] France no longer having restriction on WIFI ?‏
Importance: High

 

Dear Folks,
I had heard that as of July 1, 2012, France removed the 100 mW indoor use
requirement . Thus the Alert Symbol (!),is no longer required.
Does any one has the officail documents to verify this rumour. Please share
with me,
Thanks in advance.
 
 
Best  Regards,
jasmine

-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in
well-used formats), large files, etc.

Website: http://www.ieee-pses.org/
Instructions: http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher <[email protected]>
David Heald <[email protected]> 


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://listserv.ieee.org/request/user-guide.html
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to