Thanks John.. that makes sense. I was not sure if " parts per...." :: " mass per ...."
It explains the 120 uG/m3 (as a strange number) = 100 ppB. Regards, Ing. Gert Gremmen, BSc [email protected] www.cetest.nl Kiotoweg 363 3047 BG Rotterdam T 31(0)104152426 F 31(0)104154953 Before printing, think about the environment. -----Oorspronkelijk bericht----- Van: [email protected] [mailto:[email protected]] Namens John Woodgate Verzonden: Friday, December 14, 2012 8:32 AM Aan: [email protected] Onderwerp: Re: Ozone generating equipment In message <[email protected]>, dated Fri, 14 Dec 2012, "ce-test, qualified testing bv - Gert Gremmen" <[email protected]> writes: >How does one correlate ppB in uG/m3 ? >I remember Avogadro's number but lost the details. You need to know the mass of 1 m3 of air. While you can calculate it using elementary physical chemistry, it's easier to look it up, 1.2 kg/m3 at 20 C. So x μg/m3 = x/1.2 ppb. -- OOO - Own Opinions Only. See www.jmwa.demon.co.uk The longer it takes to make a point, the more obtuse it proves to be. John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://listserv.ieee.org/request/user-guide.html List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>

