In message <2AA1EFC0E932461392280BAFDD591F1D@lashko>, dated Fri, 8 Mar
2013, =?iso-8859-1?Q?H. K=F6ster?= <[email protected]>
writes:
Please give me your experts comments.
7.2 of IEC/EN 61000-4-5 says (among other things):
If there are no other possible connections to earth, line-to-ground
tests may be omitted.
It is really wise to have copies of the standards that are involved in
the work, especially now that low-cost sources of ENs are now available.
--