HI Ken, 

this has a dc requirement for loads greater than 400 Watts, but not less like 
most avionics boxes. UNless I missed something.


Seems like something is missing to me..


Cheers,


Derek.



-----Original Message-----
From: Ken Javor <[email protected]>
To: EMC-PSTC <[email protected]>
Sent: Mon, Sep 9, 2013 11:57 pm
Subject: Re: [PSES] AF ripple in DO-160


Derek,

Check out section 16.7 control on current ripple ac/dc, power factor, harmonic 
current.

Ken Javor
Phone: (256) 650-5261



From: Derek Walton <[email protected]>
Reply-To: Derek Walton <[email protected]>
Date: Mon, 9 Sep 2013 23:22:35 -0400
To: <[email protected]>
Subject: [PSES] AF ripple in DO-160

Hi Folks, 

the DO-160G conducted emissions limits begin at 150 kHz, I'm curious if there 
are other controlling documents that restrict emissions below 150? I believe 
Boeing does, and so does Airbus, but with DO-160 I don't see it.

I must have dozed through this discussion....

Insight would be most welcome.

Sincerely,

Derek Walton
L F Research EMC facility.
-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at: 
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:      http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to 
unsubscribe) <http://www.ieee-pses.org/list.html> 
List rules:     http://www.ieee-pses.org/listrules.html 

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]> 

For policy questions, send mail to:
Jim Bacher  <[email protected]>
David Heald <[email protected]> 

-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
&LT;[email protected]&GT;
All emc-pstc postings are archived and searchable on the web 
at:http://www.ieee-pses.org/emc-pstc.html
Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.
Website:      http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules:     http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas &LT;[email protected]&GT;
Mike Cantwell &LT;[email protected]&GT;
For policy questions, send mail to:
Jim Bacher  &LT;[email protected]&GT;
David Heald &LT;[email protected]&GT;



-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to