Hi Mark, We had a similar occurrence lately, where the Korean EMC lab tested our Class A Industrial product to ITE standards, and we failed Class B. We had previously submitted to them our EMC test report for North America and Europe, so the mistake was unexpected.
They retested to Class A at our request(at no charge that was visible to us), and we then passed the correct requirement. Best Regards, Brian C. From: Mark Schmidt [mailto:[email protected]] Sent: November-14-13 7:33 AM To: [email protected] Subject: [PSES] R&TTE Well, I have a Class A (EN55011) product under EN61326-1. Initially it was not going to be sold <adopted EN301489-1 the KN version of this standard omitted the clause in Annex C.3.1. So we <had the device tested in-country and they indicated that the unintentional radiator had to <meet Class B EN55022/CISPR 22 for ITE with 6 db margin. Naturally we failed. >This is not an ITE <product and was not designed to meet Class B any comments are appreciated. Has anyone else experienced this? Thanks, Mark Schmidt - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]<mailto:[email protected]>> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe)<http://www.ieee-pses.org/list.html> List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]<mailto:[email protected]>> Mike Cantwell <[email protected]<mailto:[email protected]>> For policy questions, send mail to: Jim Bacher <[email protected]<mailto:[email protected]>> David Heald <[email protected]<mailto:[email protected]>> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>

