It is my understanding that what you say is correct. From memory, PROVING something complies is different than VERIFYING something complies. For example, as a customer, or a monitoring entity, when 'verifying'; you are allowed a single tone over the limit, because statistically that can just happen. BUT if you are PROVING compliance and using a single unit, you should have at least 2.6dB margin to the limit. And testing 3 units, be less than the limit. Isn't that from the VDE standards years ago?
--- [email protected] wrote: From: Carpentier Kristiaan <[email protected]> To: [email protected] Subject: [PSES] Failure of Radiated emission Date: Fri, 5 Sep 2014 14:35:44 +0000 Hi group, A ITE product is tested to EN55022 Radiated emission with a well defined setup (cables, traffic, etc...) trying to find the worst case emissions and it passes. I think finding the real worst case emission for all frequencies with one and the same set-up is in practice not possible in practice. That same product is retested by a customer or in case of market surveillance campaigns, then it is most likely not tested with the same set-up and results may fail. Would this be an issue or is it acceptable that it is retested with the same set-up as the initial testing? I refer to CISPR22, clause 8.4 that states that the operational conditions of the EUT shall be determined acc. to typical use.....The operat mode and rationale shall be stated in the report. So to me it looks sufficient to test a typical set-up, do your best to not make it best case and describe everything in the report. Any other thoughts? Best regards, Kris Carpentier - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>