Hi All,
Depending on the system requirements, For mains supplied units, I like
to use the chassis of the power supply to short circuit the noise
currents so they keep inside of the supply. That usually means,
connecting through very low inductance, the circuit ground to the power
supply chassis at its output. A 4 cm wire is too long.
Doug
University of Oxford Tutor
Department for Continuing Education
Oxford, Oxfordshire, United Kingdom
--------------------------------------------------------------
___ _ Doug Smith
\ / ) P.O. Box 60941
========= Boulder City, NV 89006-0941
_ / \ / \ _ TEL/FAX: 702-570-6108/570-6013
/ /\ \ ] / /\ \ Mobile: 408-858-4528
| q-----( ) | o | Email: [email protected]
\ _ / ] \ _ / Web: http://www.dsmith.org
--------------------------------------------------------------
On 12/1/14 11:47 AM, Amund Westin wrote:
Got a DC / DC converter in an ITE.
>From a radiated emission plot, I can see lot of spikes with spacing 330kHz
in the region 30-80MHz.
The DC / DC converter datasheet tells that the switching frequency is
330kHz.
No suppression components around the converter. I assume a common mode choke
could block some on the noise, so it does not enter the power supply cable,
which may act as an antenna in this case.
Any other "tricks" for EMI suppression of DC / DC converters?
#Amund
-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc discussion
list. To post a message to the list, send your e-mail to <[email protected]>
All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html
Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used
formats), large files, etc.
Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>
For policy questions, send mail to:
Jim Bacher: <[email protected]>
David Heald: <[email protected]>
-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc discussion
list. To post a message to the list, send your e-mail to <[email protected]>
All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html
Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used
formats), large files, etc.
Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>
For policy questions, send mail to:
Jim Bacher: <[email protected]>
David Heald: <[email protected]>