In message
<CALV2MsAtFDUkBkuVCA4HONLxtWKPa43-wGZy=lfdfq24ec0...@mail.gmail.com>,
dated Mon, 9 Mar 2015, Paolo Roncone <paoloc...@gmail.com> writes:
One possible way to properly test the Line-GND surge is to use a Schuko
(or other symmetrical) AC cable/plug to couple the EUT to the Surge
CDN, turn the AC cable Schuko plug 180deg after the first L-GND surge
sequence, and repeat the same test.
In this way both AC lines of the EUT are tested the same way
(symmetrically) for Line to Ground AC surge.
I believe this is correct.
--
OOO - Own Opinions Only. With best wishes. See www.jmwa.demon.co.uk
When I turn my back on the sun, it's to look for a rainbow
John Woodgate, J M Woodgate and Associates, Rayleigh, Essex UK
-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc discussion
list. To post a message to the list, send your e-mail to <emc-p...@ieee.org>
All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html
Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used
formats), large files, etc.
Website: http://www.ieee-pses.org/
Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html
For help, send mail to the list administrators:
Scott Douglas <sdoug...@ieee.org>
Mike Cantwell <mcantw...@ieee.org>
For policy questions, send mail to:
Jim Bacher: <j.bac...@ieee.org>
David Heald: <dhe...@gmail.com>