In message <CALV2MsAtFDUkBkuVCA4HONLxtWKPa43-wGZy=lfdfq24ec0...@mail.gmail.com>, dated Mon, 9 Mar 2015, Paolo Roncone <paoloc...@gmail.com> writes:

One possible way to properly test the Line-GND surge is to use a Schuko (or other symmetrical) AC cable/plug to couple the EUT to the Surge CDN, turn the AC cable Schuko plug 180deg after the first L-GND surge sequence, and repeat the same test.

In this way both AC lines of the EUT are tested the same way (symmetrically) for Line to Ground AC surge. 

I believe this is correct.
--