MIL-STD-461 only requires CE testing on lines connected to platform primary power. If the device does not connect to platform primary power, then CE101 and CE102 do not apply. Likewise CS101 would not apply, either.
Ken Javor Phone: (256) 650-5261 From: Charlie Blackham <[email protected]> Reply-To: Charlie Blackham <[email protected]> Date: Fri, 13 Mar 2015 14:38:40 +0000 To: <[email protected]> Conversation: MIL-STD-461F - exemption for short DC leads Subject: [PSES] MIL-STD-461F - exemption for short DC leads Group Client has a piece of stand-alone equipment designed to be powered from a co-located 12/24 V battery, and will not be powered from DC distribution systems Def-Stan 59-411 has exemptions for some Conducted tests for where cables are <500mm in length is there any such exemption in MIL-STD-461F? (I couldn¹t find one) Regards Charlie Charlie Blackham Sulis Consultants Ltd Tel: +44 (0)7946 624317 LinkedIn: uk.linkedin.com/in/charlieblackham/ <http://uk.linkedin.com/in/charlieblackham/> Web: www.sulisconsultants.com <http://www.sulisconsultants.com/> Registered in England and Wales, number 05466247 - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) <http://www.ieee-pses.org/list.html> List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher <[email protected]> David Heald <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>