MIL-STD-461 only requires CE testing on lines connected to platform primary
power. If the device does not connect to platform primary power, then CE101
and CE102 do not apply. Likewise CS101 would not apply, either.

Ken Javor
Phone: (256) 650-5261



From: Charlie Blackham <[email protected]>
Reply-To: Charlie Blackham <[email protected]>
Date: Fri, 13 Mar 2015 14:38:40 +0000
To: <[email protected]>
Conversation: MIL-STD-461F - exemption for short DC leads
Subject: [PSES] MIL-STD-461F - exemption for short DC leads

Group
 
Client has a piece of stand-alone equipment designed to be powered from a
co-located 12/24 V battery, and will not be powered from DC distribution
systems
 
Def-Stan 59-411 has exemptions for some Conducted tests for where cables are
<500mm in length ­ is there any such exemption in MIL-STD-461F?
(I couldn¹t find one)
 
Regards
Charlie
 
Charlie Blackham
Sulis Consultants Ltd
Tel: +44 (0)7946 624317
LinkedIn: uk.linkedin.com/in/charlieblackham/
<http://uk.linkedin.com/in/charlieblackham/>
Web: www.sulisconsultants.com <http://www.sulisconsultants.com/>
Registered in England and Wales, number 05466247
 
-
----------------------------------------------------------------

This message is from the IEEE Product Safety Engineering Society emc-pstc
discussion list. To post a message to the list, send your e-mail to
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at
http://product-compliance.oc.ieee.org/ can be used for graphics (in
well-used formats), large files, etc.

Website:      http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to
unsubscribe) <http://www.ieee-pses.org/list.html>
List rules:     http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher  <[email protected]>
David Heald <[email protected]>



-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<[email protected]>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Attachments are not permitted but the IEEE PSES Online Communities site at 
http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used 
formats), large files, etc.

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Scott Douglas <[email protected]>
Mike Cantwell <[email protected]>

For policy questions, send mail to:
Jim Bacher:  <[email protected]>
David Heald: <[email protected]>

Reply via email to