Our lab is testing a product that uses an ISM band for it's normal functions. 
We're seeing susceptibility in that band, but IEC 61326-1 doesn't cover this 
instance. I also haven't found any EMC standards that deal with susceptibility 
in that band. CISPR 11 covers the emissions side.
Other than having the customer justify an out of tolerance in that band, is 
there something I am missing?