It's a video and audio recorder. Yes, we make use of EN55103-2 for CE marking.
But generally, still no immunity requirements in Canada? #Amund -----Opprinnelig melding----- Fra: Brian O'Connell [mailto:[email protected]] Sendt: 5. oktober 2015 22:15 Til: [email protected] Emne: Re: [PSES] EMC in Canada 'Professional' stuff would reference 55103-2, but not a Canada requirement. Do not know what your box does, but note that for A/V stuff for use with medical equipment, CSA 60601-1-2 does reference 55103-2. Brian From: Amund Westin [mailto:[email protected]] Sent: Monday, October 05, 2015 12:00 PM To: [email protected] Subject: [PSES] EMC in Canada Emission testing ITE: ICES-003 Immunity testing ITE: No requirements Is it the same approach for professional A/V products? Only emission testing? Best regards Amund - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]> - ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>