On 1/14/2016 5:20 PM, McDiarmid, Ralph wrote:
Would a Near Field probe be a better choice?

That's good for finding a source. but as Ken points out, its not accurate enough for quantitative evaluation. FWIW... a SA chamber or an OATS aren't all that hot either,according to a 2001 paper.*

*Reproducibility and Uncertainty in Radiated Emission Measurements at Open Area Test Sites and in Semi-anechoic
Chambers Using a Spherical Dipole Radiator, Tae-Weon Kang and Hyo-Tae Kim
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, VOL. 43, NO. 4, NOVEMBER 2001 677