I was taking a look at DO-160G recently, and have a question on the setup. So a current probe is used to both calibrate and measure the level of the induced transient. That level can be hundreds of amps. Why is the probe factor not taken into account? A 3 dB probe factor at 1 MHz would essentially double the required current for waveform three. I know there are some very smart people on these committees that wouldn't miss something like that. So what am I missing?
- ---------------------------------------------------------------- This message is from the IEEE Product Safety Engineering Society emc-pstc discussion list. To post a message to the list, send your e-mail to <[email protected]> All emc-pstc postings are archived and searchable on the web at: http://www.ieee-pses.org/emc-pstc.html Attachments are not permitted but the IEEE PSES Online Communities site at http://product-compliance.oc.ieee.org/ can be used for graphics (in well-used formats), large files, etc. Website: http://www.ieee-pses.org/ Instructions: http://www.ieee-pses.org/list.html (including how to unsubscribe) List rules: http://www.ieee-pses.org/listrules.html For help, send mail to the list administrators: Scott Douglas <[email protected]> Mike Cantwell <[email protected]> For policy questions, send mail to: Jim Bacher: <[email protected]> David Heald: <[email protected]>