Go for it!

Rich

 

 

From: Steve Brody <sgbr...@comcast.net> 
Sent: Friday, June 23, 2023 11:52 AM
To: EMC-PSTC@LISTSERV.IEEE.ORG
Subject: [PSES] Machine status visual Indicators

 

Experts, 

  

I have a client who would like to use a single LED capable of multiple colors 
instead of a mutli-lamp light tower that we are used to seeing. 

  

It can produce the required colors in accordance with 60204-1, Table 4. 

  

I have read through 60204-1 (machinery) safety and 61310-1 (requirements for 
visual, acoustic, and tactile signals) and did not find anything that prohibits 
the use of a single LED. 

  

Thoughts? 

  

  

  

Steve Brody 

sgbr...@comcast.net <mailto:sgbr...@comcast.net>  

C - 603 617 9116 


-
----------------------------------------------------------------
This message is from the IEEE Product Safety Engineering Society emc-pstc 
discussion list. To post a message to the list, send your e-mail to 
<emc-p...@ieee.org>

All emc-pstc postings are archived and searchable on the web at:
http://www.ieee-pses.org/emc-pstc.html

Website:  http://www.ieee-pses.org/
Instructions:  http://www.ieee-pses.org/list.html (including how to unsubscribe)
List rules: http://www.ieee-pses.org/listrules.html

For help, send mail to the list administrators:
Mike Cantwell <mcantw...@ieee.org>

For policy questions, send mail to:
Jim Bacher:  <j.bac...@ieee.org>
David Heald: <dhe...@gmail.com>
_________________________________________________
To unsubscribe from the EMC-PSTC list, click the following link: 
https://listserv.ieee.org/cgi-bin/wa?SUBED1=EMC-PSTC&A=1

Reply via email to