Chris Radek wrote: >On Sat, May 26, 2007 at 07:14:06AM -0400, Jack Ensor wrote: > > >>I plan on wiring momentary push button switches in parallel with the >>appopriate short cut keys on the keyboard. One of the problems I see is >>that of providing for the 2 key combination required for the Home-All >>function. I assume that the key assignment can be changed in software >>and hope someone can give me insight into how this could be done. >> >>Jack Ensor >> >> > >A better approach for a control panel would be to use halui. See the >integrator's manual which describes how to use it. The manual may >be slightly out of date regarding the available inputs, so use >halcmd/halshow to examine them on a running EMC2. > >Chris > > > > I don't have enough input pins left on the on the my three parallel ports unless I reconfigure some of the ports to input. This means a complete replacement and rewiring of of the existing flat cables and reprogramming and checkout of the now working system.
Another alternative may be to add another parallel port board to provide more parallel ports. The current add-on board which provided 2 parallel ports, had the addresses preassigned and adding another identical board would surely have an address conflict. How can I add additional parallel ports and avoid address conflicts? Jack Ensor ------------------------------------------------------------------------- This SF.net email is sponsored by DB2 Express Download DB2 Express C - the FREE version of DB2 express and take control of your XML. No limits. Just data. Click to get it now. http://sourceforge.net/powerbar/db2/ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users