G41 and G42 D use the <int> as a reference to the tool table. G41.1 and G42.1 use the <int> as the immediate tool diameter to use G43 uses the <int> as a reference to the tool table. G43.1 uses the I<int>,K<int> as the immediate compensation values (X & Z).
Regards, Alex PS: this is my interpretation of: http://www.linuxcnc.org/docview/html/gcode_main.html#sub:G40,-G41,-G42: ----- Original Message ----- From: "Matthew Glenn Shaver" <[EMAIL PROTECTED]> To: "Enhanced Machine Controller (EMC)" <emc-users@lists.sourceforge.net> Sent: Monday, January 14, 2008 4:52 AM Subject: [Emc-users] Tool Table - POC vs FMS >I have an EMC2 based system that I've been working with for a very short > time, I think it's 2.2.1. I've observed (possibly incorrectly) that in a > block containing G43H<int>, the <int> references the FMS field of > records in the tool table, whereas in a block containing G[41 or > 42]D<int>, the <int> seems to refer to the POC field. > > Are these observations correct? If so, why is it this way? > > Thanks, > Matt > > > > ------------------------------------------------------------------------- > Check out the new SourceForge.net Marketplace. > It's the best place to buy or sell services for > just about anything Open Source. > http://ad.doubleclick.net/clk;164216239;13503038;w?http://sf.net/marketplace > _______________________________________________ > Emc-users mailing list > Emc-users@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/emc-users > ------------------------------------------------------------------------- Check out the new SourceForge.net Marketplace. It's the best place to buy or sell services for just about anything Open Source. http://ad.doubleclick.net/clk;164216239;13503038;w?http://sf.net/marketplace _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users