John Kasunich wrote:
> Jon Elson wrote:
> 
> 
>>Well, I don't know how well these will perform.  The Fanuc A06B 
>>series of phase-control servo amps ran off 3-phase power, so 
>>they had 360 conduction pulses a second possible.  If the Gettys 
>>amps run off single-phase, they have only 120 possible 
>>conduction pulses, which cuts severely into bandwidth. 
> 
> 
> I'd be astonished if they are single phase.  Stuart is working on a real
> machine (Cincinnati 5-axis) in a real shop with real electricity.
> 
> See http://willepadnos.net/jmkasunich/mpm_cinc508.jpg
I know, and the Fanuc amps are always 3-phase, but a number of 
the Gettys models WERE single-phase, with all the obvious 
problems that could cause.  It saves on SCRs and control 
circuits, of course.

Jon

-------------------------------------------------------------------------
This SF.net email is sponsored by the 2008 JavaOne(SM) Conference 