On Mon, 2008-10-27 at 13:53 -0600, Grant Hess wrote: > I'm not sure where my previous replies went, but they seem to have > evaporated. > > I do have a loop back signal from iocontrol.0.tool-preprare to > iocontrol.0.tool-prepared and it appears to function correctly when a > Txx gcode is presented. > > I have also checked to ensure that the the switch on the panel is > actually linked to the iocontrol.0.tool-changed pin correctly. > Halmeter shows it change to true when I press the switch. > > Thanks, > Grant.
I have this on my lathe: ... # create signals for tool loading loopback linkpp iocontrol.0.tool-prepare iocontrol.0.tool-prepared linkpp iocontrol.0.tool-change turret.0.position-change linkpp turret.0.position-changed iocontrol.0.tool-changed ... Which works fine. Do you have your iocontrol.0.tool-change connected to something? If not, I wonder if EMC2/AXIS is taking this as an incomplete setup. In the past I have placed dummy connections in the config files to get them to show up in AXIS. Just a guess. Kirk ------------------------------------------------------------------------- This SF.Net email is sponsored by the Moblin Your Move Developer's challenge Build the coolest Linux based applications with Moblin SDK & win great prizes Grand prize is a trip for two to an Open Source event anywhere in the world http://moblin-contest.org/redirect.php?banner_id=100&url=/ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users