On Fri, 2008-12-26 at 10:55 -0800, Kirk Wallace wrote: > I noticed that EMC2 has a charge pump output. Does anyone have a charge > pump input HAL component? One example of its use, might be for limit and > home switches, so that any switch fault (short to ground or supply or > open) could be detected. Or, maybe this should be done in hardware, > independently of software, but if the software crashes the e-stop charge > pump should activate?
With a little more thought, a dual frequency detector, for "open" and "closed" would be needed. Or an AC pump and DC level detector. A software DTMF decoder component would allow for more states to be detected. ------------- Kirk http://www.wallacecompany.com/machine_shop/ ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/emc-users