Tom wrote:
> Is there an argument to 
> loadrt hal_parport cfg="0x0378"
> that will set the normally output only pins 1-9 to bidirectional, or to input?
> 

I believe cfg="0x0378 in" will work (or maybe the "in" comes first, then
the address - the proper syntax is definitely in the manual).  That will
set pins 2 thru 9 to input instead of output.  Pin 1 is what it is -
there is no way to turn it around ( hardware limitation ).