> Frank Tkalcevic wrote:
>   
>> How do you generate your step pulses?  When I was tunning, I would keep the
>> machine on and do an MDI move.  This doesn't work too well when the tuning
>> is so bad it faults when you enable the machine.
>>   
>>     
Hmm, looks like I missed part of your question.  If it is faulting 
immediately, there may be a reversal of the motor wires, or some other 
reason the servo diverges, when it is supposed to converge.  I show that 
sort of response in one of the pictures on my tutorial.  If you turn the 
gain down, then you may be able to keep it from going wild immediately.
I have software-controlled following error in EMC, not in the drive, so 
I can set it quite wide when starting out.

Jon

------------------------------------------------------------------------------