On Mon, Aug 31, 2009 at 12:25:23AM +0200, Thorsten Seefeldt wrote:

> G3 X  90.000 Y -10.000 I -10.000 (Arc out of cut path)
> G40 (Turn off Cutter Compensation)

Sorry, my earlier advice was bad because I didn't even look at this.

This arc is just wrong - try taking out the G41 and run without
comp.  You will see it's just not what you meant.

I'm pretty sure you meant J, not I

And you do it exactly right, leaving cutter comp on until you're
away from the part edge.

Chris

------------------------------------------------------------------------------