2009/11/20 Leslie Newell <les.new...@fastmail.co.uk>:

> Carbon dioxide is 66% oxygen (CO2). As aluminum is very active it will
> strip oxygen out of the CO2.

The electronegativity of Al is 1.6, and that of iron is 1.8 (cf 2.5 for Oxygen)
CO2 works perfectly well as a shielding gas for MIG welding of steel
at molten temperatures, I would not anticipate it reacting strongly
with Al at machining temperatures.

I have MIG welded aluminium with CO2 shielding gas, and it worked
(whilst being demonstrably non-ideal)

-- 