Hi Ted; I have spent the whole day trying to get the data off my system to send to the people who think they can find the problem when can get a halshow file to them. The computer was very stubborn. Finally had to drive sixty miles to the local store to get a Flash Drive to extract the data.
As soon as I know something I'll pass it on. Thanks Don ----- Original Message ----- From: "Ted Hyde" <laser...@gmail.com> To: <emc-users@lists.sourceforge.net> Sent: Friday, May 21, 2010 5:13 PM Subject: [Emc-users] EMC2 Homing with Index Pulse > Don - I am running with 2.3.0 with a Mesa 5i20 and am noticing the same behavior; I have at least for the moment returned to mode 2 (home switch use only) as that is currently sufficient; my initial expectation was that an unfinished part of my system may have been at fault. It's a servo system, separate limit +/-, separate overtravel +/-, separate home for each axis (total 5 sw per axis, nothing shared), running encoders as hostmot2 modules, and the index pulse does occur. If I use mode 3 or 4 for homing, the do_homing() proc doesn't appear to see the index pulse at all and continues to the overtravel limit. I can reset count signals with the .index-enable, so I believe the hostmot2 and hardware are fine. > > I expect there is an additional "....encoder.xx.index-enable 1" or equivalent required for the system to actually use the index, however in my earlier dealings with the hostmot2 I thought that particular parameter was to clear the position counter on the next index pulse, instead of being used by another part of EMC; and thus you would have to set that parameter true every time you wanted to clear the position. I may of course be, way off, however it is also described this way in the current man page for hostmot2. I was unable to find any additional requirement to set it true for homing use. > > (EDIT: ....encoder.xx.index-enable 1 does indeed work as described in the hostmot2 man page; verified just now on my lathe. I can't see how one would use the same parameter for the homing setup). > > Ted. > > > > EKCo Inc Don Stanley wrote: > > > > Hi All; > > > I have installed EMC 2.3 on a lathe using the Motenc Light interface. > > > Two problems have me stumped. > > > > > > 1- I want to Home at the Encoder Index after using Plus-limit / Home > > > combination Switch at the Plus end of travel to get to a known start > > > position. This is shown in the third homing diagram on the page > > > of four diagrams in the Integrator Manual INI file homing section. > > > > > > I can't stop if from Homing at the "Home Switch release point". > > > Does anyone know how to make this work with my equipment? > > > > -------------------------------------------------------------------------- ---- > > _______________________________________________ > Emc-users mailing list > Emc-users@lists.sourceforge.net > https://lists.sourceforge.net/lists/listinfo/emc-users ---------------------------------------------------------------------------- ---- No virus found in this incoming message. Checked by AVG - www.avg.com Version: 9.0.819 / Virus Database: 271.1.1/2887 - Release Date: 05/21/10 02:26:00 ------------------------------------------------------------------------------ _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users