On Mon, 2010-12-20 at 15:11 -0600, Jeff Epler wrote:
> My first impression is that there is no "an index occurred" output, so I
> don't see how you would make it work with emc's index-enable model for
> threading and home-to-index.
> 
> Jeff

A brief look doesn't indicate (to me) what it uses the index for (reset
the internal counter?). My first guess is that I would leave it
unconnected and route the index to EMC2 on another path. The index
question seems to be the only deal breaker.

With four bytes of counter, it seems I could hold the position for long
axes even with 10k ppr, .00002"/p and count a high speed.
-- 
Kirk Wallace
http://www.wallacecompany.com/machine_shop/