On 1 March 2011 06:11, Igor Chudov <ichu...@gmail.com> wrote: > So. How would I somehow configure EMC to stop providing any current to "W", > when not really moving it?
I can think of two ways, either of which might work. More "I" term might might allow the current to build up to a high enough level to actually hit the setpoint. Alternatively, setting a deadband in the PID might do the trick (though I suspect that, actually, it would just end up sat at the bottom of the deadband getting just as warm) -- atp "Torque wrenches are for the obedience of fools and the guidance of wise men" ------------------------------------------------------------------------------ Free Software Download: Index, Search & Analyze Logs and other IT data in Real-Time with Splunk. Collect, index and harness all the fast moving IT data generated by your applications, servers and devices whether physical, virtual or in the cloud. Deliver compliance at lower cost and gain new business insights. http://p.sf.net/sfu/splunk-dev2dev _______________________________________________ Emc-users mailing list Emc-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/emc-users