Yes, I have done this. Try:
script --> hal command --> CL input
Sometimes in combination with:
PyVCP input --> CL input
And you might need the handy script-wait-for here:
http://wiki.linuxcnc.org/cgi-bin/emcinfo.pl?CustomMcodesToHal

Kim


On 04/27/2011 01:51 PM, David Winter wrote:
> Dear All,
> Is it possible for a programmed M-code to affect a 
> facility in Classic Ladder, e.g
> move a value into a register or set a flag or marker?
> 
> Thanks in advance,
> 
> David Winter.
> 
> 
> 
> ------------------------------------------------------------------------------