2011/9/27 Kirk Wallace <[email protected]>:
>
> There seems to be a step/dir input, either through the RS232 PC port or SSI
> port. The PC connection seems simple enough, a simple RS232 three wire,
> Rx, Tx and Ground or CAN.
>
> What kind of motors and application is this for?

The drives are fitted with AC servo motors with resolvers on them.
What I did is retrofit of CNC controls on waterjet cutting machine. At
first I had them in step/dir mode, now I wanted them in "normal" mode
with analog signal and 2 feedback devices in EMC.

The thing is that I got 2 motors oscillating (due to untuned feedback
loop) but the third motor did not move. It turned out that servo drive
was showing error and thus not moving motor at all, so I did not even
get to finetuning feedback loop (and to all the questions for the
list, how to actually do it).

Viesturs

------------------------------------------------------------------------------